July 23, 2001
    AccommoDATE Level 2R2 Release Announcement
                    
                    
    
        General
    
        Formula Consultants is pleased to announce that Level 2R2 of AccommoDATE is now
        available for distribution. As is standard with FCI policy, this release will be
        provided at no additional cost to all AccommoDATE users with current maintenance
        contracts, as well as to users who are still in their initial warranty period.
    
                    
    
        Product Overview
    
        AccommoDATE can assist businesses facing extensive date testing by enabling them
        to set a simulated date for program testing without having to reboot and without
        affecting costly production runs. It enables users who have a single system, or
        those who must use time on a production system, to test their software with different
        dates even when that system was booted with the current date. In other words, AccommoDATE
        lets you test batch runs, demand runs, and TIP transactions using a date other than
        the current system date.
    
    
    
        AccommoDATE:
    
    
        
            - Does not require booting the system with a simulated test date
 
            - Is activated by a keyin from a system console
 
            - Enables testing of a variety of programs over a range of dates
 
            - Allows different programs to be tested simultaneously, each using
                different dates
 
            - Requires no changes to existing runstreams or programs
 
            - Allows programs to be placed directly into production after testing,
                without code modifications.
 
        
     
    
    
        Release Description
    
        AccommoDATE level 2R2 is a minor enhancement release.
    
    
        Minor Enhancements
    
        New Product Modification Element for HMP 6.0 and HMP 6.1
        The new Product Modification Element HMP6 has been introduced to support EXEC Levels
        46R3 and 46R4.
    
        New Product Modification Element for HMP 6.1 EXEC 46R4S
        The new Product Modification Element HMP61S has been introduced to support EXEC
        Level 46R4S.
    
    
        New Product Modification Element for HMP 6.1 EXEC 46R5, 46R5S
        The new Product Modification Element HMP61V has been introduced to support EXEC
        Levels 46R5 and 46R5S.
    
        New Product Modification Element for HMP 7.0
        The new Product Modification Element HMP7 has been introduced to support EXEC Level
        46R6.
    
    
    
        AccommoDATE Notes of Interest
    
        AccommoDATE corrections described by Notes of Interest up to number 8 are included
        in level 2R2.
    
    
        Restrictions and Limitations
    
        UCS object module execution must be supported. This includes support for extended
        mode by the Exec as well as installation of the LINK and URTS products. Be aware
        that UNISYS does not support an upward compatible LINK between System Base Releases.
        For example, it would not be possible to generate AccommoDATE under SB5 and install
        it under SB4.
    
        The following table shows the System Base/HMP Levels and their associated Exec Levels
        which are supported in AccommoDATE. The SB7 PME should be used to install AccommoDATE
        under Exec level 45R2 in HMP 3.0. The HMP3 PME is compatible with HMP 3.0 only if
        UNISYS CHG #00006-70354-PCR is installed on your system. This change is already
        integrated in HMP 3.1.
    
        
            
                
                
            
            
                | 
                    SB / HMP Level
                 | 
                
                    Exec Levels
                 | 
            
            
                | 
                    SB4
                 | 
                
                    43R8
                 | 
            
            
                | 
                    SB5
                 | 
                
                    44R4, 44R4A, 44R4B, 44R4C, 44R4D
                 | 
            
            
                | 
                    SB6
                 | 
                
                    45R1, 45R1A, 45R1B, 45R1C, 45R1D
                 | 
            
            
                | 
                    SB7, HMP3.0
                 | 
                
                    45R2
                 | 
            
            
                | 
                    HMP3.1
                 | 
                
                    45R2A
                 | 
            
            
                | 
                    HMP4
                 | 
                
                    46R1, 46R1A, 46R1B, 46R1C, 46R1D
                 | 
            
            
                | 
                    HMP5
                 | 
                
                    46R2, 46R2A
                 | 
            
            
                | 
                    HMP6
                 | 
                
                    46R3
                 | 
            
            
                | 
                    HMP61S
                 | 
                
                    46R4, 46R4S
                 | 
            
            
                | 
                    HMP61V
                 | 
                
                    46R5, 46R5S
                 | 
            
            
                | 
                    HMP7
                 | 
                
                    46R6
                 | 
            
        
     
    
        We recommend creating or using an application group for AccommoDATE testing that
        is independent of your production application groups. This will prevent any problems
        in integrated recovery caused by mixing timestamps from various applications. An
        alternative to creating a unique application group is running your programs in test
        or training mode. This will prevent any use of production databases.
    
    
    
        Compatibility and Migration
    
        Release 2R2 is generated under HMP 5.1 and tested under 46R2, 46R2A, 46R3, 46R4,
        46R4S, 46R5, 46R5S, and 46R6.
    
    
        Documentation
    
        Documents provided with release 2R2 include:
    
        
            - AccommoDATE Installation and Administrator Guide, FP-151-2R2
            
 
            - AccommoDATE Level 2R2 Release Announcement 
 
        
     
    
    
        FCI Website
    
        You may obtain general information about Formula Consultants Inc. and its products
        at our website at www.formula.com.
        Once you register with the site and receive a userid and password, you can also
        download PCRs and Notes of Interest. Product documentation in PDF format is also
        available (Adobe Acrobat™ Reader required).
    
    
        FCI Support Center
    
        Effective with the release of AccommoDATE 2R2, the FCI Support Center (FCISC) is
        available for use. The FCISC is a 2200 host server software system that is accessible
        by using the standard UNISYS Remote Site Support (RSS) product. It allows you to
        send and receive data electronically to and from FCI. Refer to the AccommoDATE Installation
            and Administrator Guide for more information.
    
    
        Corrections
    
        File 13 on your release tape contains PCRs, if any, that have been generated against
        this release, as of the date your tape was created. Include any of these corrections
        applicable to your site with the first build from this tape. AccommoDATE elements
        are a combination of basic and UCS elements so the PCRs are organized by AccommoDATE
        processor type (basic mode or UCS). These elements can be @ADDed following an @COMUS
        to enter the corrections into your local COMUS database. You should examine the
        file to determine which elements should be added to your build.
    
        The elements README, CHGNUM-ALL, and ACMDT-NOIS are informational only and should
        not be @ADDed to your COMUS database.
    
        The possible elements in File 13 are:
    
        
            
                
                
            
            
                | 
                    README
                 | 
                
                    explanation and cutoff date/time
                 | 
            
            
                | 
                    ADD/SGS
                 | 
                
                    changes for the ‘additional SGS’ build prompt
                 | 
            
            
                | 
                    BASE/version
                 | 
                
                    changes to AccommoDATE elements
                 | 
            
            
                | 
                    CHGNUM-ALL
                 | 
                
                    list of all change numbers
                 | 
            
            
                | 
                    ACMDT-NOIS
                 | 
                
                    all relevant Notes of Interest
                 | 
            
        
        
        
            where:
        
            version can be BASIC or UCS depending on the associated AccommoDATE element.
            The CHG numbers generated by COMUS must be entered at the ‘New Change number’ build
            prompt. These numbers can be entered individually, or @ADD the CHGNUM elements that
            apply to your build.
        
     
    If you add UCS corrections, the UCOB and/or UC compilers
    must be installed. Another method of including UCS corrections is to copy updated object
    modules contained in this file. This is done by answering the build prompt, Any
    replacement Object Modules to be included, and specifying the filename into which
    the modules were copied.
    File 13 of your release tape also contains Notes of
    Interest in the element called ACMDT-NOIS. Notes of Interest are field bulletins which we
    recommend reading prior to generating or installing AccommoDATE.
    
    Contact Information
    
        To learn more about this product, go to the 
        
            AccommoDATE Product Page
    
    
        Click below to:
            Order an
            AccommoDATE Overview
            Order latest
            AccommoDATE release
    
    
        To contact an FCI Sales Representative, call or fax us at:
        Telephone: (714) 778-0123 ext. 0
        Fax: (714) 778-6364
        - or -
        send us a Web Mail message.